Journal of Environmental Research And Development | Volume 4 No. 2 Oct.-Dec 2009 |
ORGANIC RANKINE CYCLE POWERED COMPRESSION REFRIGERATION CYCLE : AN EXERGETIC MODEL
Maneesh Dubey*and S.P.S. Rajput
Department of Mechanical Engineering, MANIT, Bhopal - 462051 (INDIA)
*E-mail : d.maneesh@gmail.com
Received on August 20,2009 and accepted on December 02, 2009
ABSTRACT
The conventional approach followed for the evaluation of a coupled power-refrigeration cycle using the first law of thermodynamics is proposed to be substituted by analyzing it from the viewpoint of second law of thermodynamics. This paper describes that exergy clearly identifies efficiency improvements and reductions in thermodynamic losses paving the way for the adoption of green technologies. Exergy can be used to assess and improve energy systems by providing more useful and meaningful information than energy analysis. This article focuses on the development and state-of-the art of exergy analysis by leveraging conventional concepts. The thermodynamic models for energy and exergy analysis for computing performance parameters are presented in this paper.
Keywords : Energy, Exergy, Exergetic efficiency, Exergy destruction, Performance, Efficiency.